Spin Warp Imaging
 
A form of Fourier transformation imaging in which phase encoding gradient pulses are applied for a constant duration but with varying amplitude. The spin warp method, as other Fourier imaging techniques, is relatively tolerant of inhomogeneities in the magnetic fields.
spacer
MRI Resources 
Pediatric and Fetal MRI - Pathology - Lung Imaging - MRI Technician and Technologist Jobs - Homepages - Non-English
 
Synchronization, Respiratory
 
The respiratory phase can be used to control imaging either by only acquiring the image data during a particular portion of the respiratory cycle (which increases image acquisition time) or by adjusting the sequence of image data collection according to the phase of the respiratory cycle in such a way as to minimize motion-induced artifacts in the reconstructed image.

See also Respiratory Ordered Phase Encoding.
spacer
MRI Resources 
MRI Technician and Technologist Schools - Functional MRI - Portals - Image Quality - Mass Spectrometry - Bioinformatics
 
Variable Flip Angle
 
The temporal variation of the flip angle (from one RF pulse to the next) to enhance SNR, and/or equalize the signal intensity for each phase encoding step.
spacer

• View the DATABASE results for 'Variable Flip Angle' (4).Open this link in a new window


• View the NEWS results for 'Variable Flip Angle' (1).Open this link in a new window.
 
Further Reading:
  Basics:
A practical guideline for T1 reconstruction from various flip angles in MRI
Saturday, 1 October 2016   by journals.sagepub.com    
Searchterm 'Phase Encoding' was also found in the following service: 
spacer
Forum  (5)  
 
ViewForum -
related threads
 
The ensemble of raw data points collected during the signal readout. For example, during Cartesian sampling, normally used to refer to data collected with a fixed value of the phase encoding gradient. Also referred to as one line of k-space. In projection reconstruction, the line is radial oriented, while in spiral imaging, it is a spiral.
spacer

• View the DATABASE results for 'View' (160).Open this link in a new window


• View the NEWS results for 'View' (20).Open this link in a new window.
 
Further Reading:
  Basics:
Image Characteristics and Quality
   by www.sprawls.org    
MRI Resources 
Pathology - Safety pool - Devices - Services and Supplies - Movies - Liver Imaging
 
previous      71 - 74 (of 74)     
Result Pages : [1 2]  [3 4 5 6 7 8 9 10 11 12 13 14 15]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Next big thing in MRI will be :
AI 
remote operator 
personalized protocols 
helium-free 
molecular MRI 
portable MRI 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 27 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]